NTC and PTC Thermistor Sensors in Ohms:
Temp deg C |
-40 |
-30 |
-20 |
-10 |
0 |
10 |
20 |
30 |
40 |
50 |
60 |
70 |
80 |
90 |
100 |
110 |
120 |
130 |
140 |
150 |
Std Bosch NTC |
45313 |
26114 |
15462 |
9397 |
5896 |
3792 |
2500 |
1707 |
1175 |
834 |
596 |
436 |
323 |
243 |
187 |
144 |
113 |
89 |
72 |
55 |
Bosch 280 130 017 |
22000 |
15000 |
10000 |
6070 |
3770 |
2450 |
1650 |
1070 |
726 |
527 |
370 |
272 |
204 |
157 |
120 |
93 |
80 |
69 |
61 |
55 |
Hella 6PT 009 109 041 |
65500 |
65000 |
55000 |
29556 |
17644 |
10773 |
6600 |
4077 |
2600 |
1800 |
1260 |
878 |
626 |
459 |
353 |
267 |
205 |
165 |
130 |
110 |
Delphi AC IAT |
65500 |
51791 |
28146 |
15873 |
9256 |
5572 |
3457 |
2205 |
1443 |
965 |
660 |
462 |
329 |
238 |
175 |
131 |
99 |
76 |
59 |
47 |
Delphi AC ECT |
65500 |
52594 |
28582 |
16120 |
9399 |
5658 |
3511 |
2240 |
1465 |
980 |
671 |
469 |
334 |
242 |
178 |
133 |
101 |
78 |
60 |
48 |
Autronic KTY83 |
577 |
632 |
691 |
754 |
850 |
889 |
962 |
1039 |
1118 |
1202 |
1288 |
1379 |
1472 |
1569 |
1670 |
1774 |
1882 |
1993 |
2107 |
2225 |
NTC and PTC Thermistor Sensors in Volts:
NOTE: This table is a calculation based upon the above values with a 1k Ohm pull-up resistor between the pin and 5V power source.
Temp deg C |
-40 |
-30 |
-20 |
-10 |
0 |
10 |
20 |
30 |
40 |
50 |
60 |
70 |
80 |
90 |
100 |
110 |
120 |
130 |
140 |
150 |
Std Bosch NTC |
4.892 |
4.816 |
4.696 |
4.519 |
4.275 |
3.957 |
3.571 |
3.153 |
2.701 |
2.274 |
1.867 |
1.518 |
1.221 |
0.977 |
0.788 |
0.629 |
0.508 |
0.409 |
0.336 |
0.261 |
Bosch 280 130 017 |
4.783 |
4.688 |
4.545 |
4.293 |
3.952 |
3.551 |
3.113 |
2.585 |
2.103 |
1.726 |
1.350 |
1.069 |
0.847 |
0.678 |
0.536 |
0.425 |
0.370 |
0.323 |
0.287 |
0.261 |
Hella 6PT 009 109 041 |
4.925 |
4.924 |
4.911 |
4.836 |
4.732 |
4.575 |
4.342 |
4.015 |
3.611 |
3.214 |
2.788 |
2.338 |
1.925 |
1.573 |
1.305 |
1.054 |
0.851 |
0.708 |
0.575 |
0.495 |
Delphi AC IAT |
4.925 |
4.905 |
4.828 |
4.704 |
4.512 |
4.239 |
3.878 |
3.440 |
2.953 |
2.455 |
1.988 |
1.580 |
1.238 |
0.961 |
0.745 |
0.579 |
0.450 |
0.353 |
0.279 |
0.224 |
Delphi AC ECT |
4.925 |
4.907 |
4.831 |
4.708 |
4.519 |
4.249 |
3.892 |
3.457 |
2.972 |
2.475 |
2.008 |
1.596 |
1.252 |
0.974 |
0.756 |
0.587 |
0.459 |
0.362 |
0.283 |
0.229 |
Autronic KTY83 |
1.829 |
1.936 |
2.043 |
2.149 |
2.297 |
2.353 |
2.452 |
2.548 |
2.639 |
2.729 |
2.815 |
2.898 |
2.977 |
3.054 |
3.127 |
3.198 |
3.265 |
3.329 |
3.391 |
3.450 |
Honda Type A temperature sensors:
Honda Type A calibration can be used for IAT and ECT sensors found in:
L15A (ECT)
L15B (ECT and IAT)
Link MAP sensor Calibration:
See Link MAP Sensors for identification information
1.15 Bar (MAP1.15) PCLink: Link 1.15 Bar
VDC |
kPa (psiA) |
0.2 |
15 (2.176) |
4.7 |
115 (16.68) |
2.5 Bar (MAP2.5) PCLink: Link 2.5 Bar*
VDC |
kPa (psiA) |
0.2 |
20 (2.9) |
4.9 |
250 (36.26) |
3 Bar (MAP3) PCLink: Link 3 Bar
VDC |
kPa (psiA) |
0.3 |
20 (2.9) |
4.9 |
300 (43.5) |
4 Bar (MAP4) PCLink: Link 4 Bar*
VDC |
kPa (psiA) |
0.2 |
20 (2.9) |
4.8 |
400 (58.02) |
5 Bar (MAP5) PCLink: Link 5 Bar
VDC |
kPa (psiA) |
0.5 |
0 (0) |
4.361 |
500 (72.52) |
6.5 Bar (MAP6.5) PCLink: Link 6.5 Bar
VDC |
kPa (psiA) |
0.5 |
0 (0) |
4.5 |
689.476 (100) |
* Any Link branded 2.5 or 4 Bar MAP sensors can use these calibrations.
Calibration Name |
Low Voltage |
Low Lambda |
Low AFR (Gasoline) |
High Voltage |
High Lambda |
High AFR (Gasoline) |
Innovate LC1 |
0 V |
0.500 |
7.35 |
5.00 V |
1.523 |
22.39 |
NGX AFX |
0 V |
0.612 |
9.00 |
5.00 V |
1.088 |
16.00 |
Autronic 0-5 V |
0 V |
0.680 |
10.00 |
5.00 V |
2.041 |
30.00 |
Autronic 0-1 V |
0 V |
0.680 |
10.00 |
1.00 V |
2.041 |
30.00 |
Zeitronix Zt-3 |
0 V |
0.653 |
9.60 |
5.00 |
1.333 |
19.60 |
AEM X-Series |
< 0.50 |
0.58 |
8.50 |
>4.50 |
1.23 |
18.00 |