The G4X SupraLink Plug-in ECU has two CAN buses. These CAN buses exist to support aftermarket CAN devices.
CAN bus 1 uses a 5 pin connector and is labeled on the ECU as 'CAN 1/RS232'.
If using this connector for CAN ensure the cable being used doesn't have Serial wires connected as this can act as an aerial and prevent USB communications from working.
CAN 1/RS232 Connector |
||
Pin |
Function |
Colour |
1 |
Comms GND |
Brown |
2 |
CAN1 L |
Green |
3 |
CAN1 H |
White |
4 |
RS232-RX |
Grey |
5 |
RS232-TX |
Yellow |
CAN bus 2 uses a 5 pin connector and is labeled on the ECU as 'CAN 2/OBD'.
CAN 2/OBD Connector |
||
Pin |
Function |
Colour |
1 |
GND |
Brown |
2 |
CAN2 L |
Green |
3 |
CAN2 H |
White |
4 |
NC |
Grey |
5 |
+14V |
Yellow |
To learn more about CAN see PCLink help.