12 Volt Internal

This shows the measured voltage of the ECUs 12V internal regulated voltage supply.

 


3.3V Internal

This shows the measured voltage of the ECUs 3.3V internal regulated voltage supply.

 


5V Analog Supply (Status)

The following are the possible states of the 5 volt external Analog supply status:

 

·OK No faults detected.

·ERROR - Fault detected. Check wiring and sensors.

 


5V Out

This value shows the measured voltage on the ECUs 5V out supply. This supply is used to provide a reference voltage for sensors such as the MAPS sensor and TPS and so it is important that this value remains close to 5V. A low voltage may indicate a wiring fault, sensor failure or ECU failure.

 

 


8V Out

This value shows the measured voltage on the ECUs 8V out supply. It is important that this value remains close to 8V, a low voltage may indicate a wiring fault, sensor failure or ECU failure.

 


Aux 9/10 Status

The status of the supply voltage of Auxiliary Output 9/10, these Auxiliary Outputs require this pin to supply power to the drivers in order for them to operate correctly as well as for high side driving.

 


Aux 9/10 Supply

The voltage reading of the Auxiliary Output 9/10 supply voltage, these Auxiliary Outputs require this pin to supply power to the drivers in order for them to operate correctly as well as for high side driving.

 


ECU Temperature

This value shows the current ECU internal temperature. It is not recommended to operate the ECU at temperatures below -20 degrees C or above 70 degrees C.

 


Fault Codes (Status)

Stores the state all fault codes in a structure.

 


Fault Code Count

The number of fault codes currently active in the ECU. To view the fault codes click View > Event Log in PCLink.

 


Fuel Calculation (Status)

Displays the state of the ECUs fueling calculation. Errors can occur due to abnormal values entered in configuration options of fuel tables.

The following are the possible states of the Fuel Calculation Status:

·OK No faults detected.

·ERROR LOW - Fuel calculation clamped at it's minimum value.

·ERROR HIGH - Fuel calculation clamped at it's maximum value.

·ERROR MAX DC - Maximum injector duty cycle reached.

 


Trigger 1&2 Arming

The actual measured arming voltage on trigger 1 & 2 respectively.

 


Dataflash Checksum

Indicates the status of the basemap and logging memory.

 


Hardware Block 1 (Status)

Indicates the status of the trigger hardware.

 


Hardware Block 2 (Status)

Indicates the status of the trigger 1 arming voltage hardware.

 


Hardware Block 3 (Status)

Indicates the status of the trigger 2 arming voltage hardware.

 


Password Protection (Status)

Indicates whether or not password protection is currently active.

 


Table Allocation (Status)

Indicates if there was a fault while allocating tables.

 


Aux 11-16 Driver Status

Indicates if there is a problem with the aux 11-16 driver.

 


Database Error

indicates if there is a problem with the settings/runtimes database.

 


Database ID Error

indicates where in the settings/runtimes database the problem is.