DISCLAIMER
These setting are provided as a general guide only. It is the installers/tuners responsibility to check and confirm that all of these settings are correct for the application.
Configuration |
||
4 Stroke |
||
4 |
||
1 - 3 - 4 - 2 |
||
Ignition Setup |
||
Wasted Spark |
||
Falling (Dwell Edge = Rising) |
||
Installer to set |
||
Trigger Setup |
||
Mitsubishi EVO 1-6 |
||
Trigger 1 |
||
Optical/Hall |
||
ON |
||
All |
||
Trigger 2 |
||
Optical/Hall |
||
ON |
||
All |
Recommended Knock Filter (Bosch aftermarket sensor): 6kHz Narrow Band Filter.
For more information or corrections to this information please contact tech support.