Configuration


Engine Type

4 Stroke


Cylinders/Rotors

4


Firing Order

1 - 3 - 4 - 2

Ignition Setup


Ignition Mode

Direct Spark


Spark Edge

Falling (Dwell Edge = Rising)


Ignition Delay

Installer to set

Trigger Setup


Trigger Mode

Toyota 1ZZ VVT - Note: Some use Toyota 2NZ VVT trigger mode.

Trigger 1


Trigger 1 Type

Reluctor


Trigger 1 Filtering

Level 1 (Low)


Trigger 1 Arming Threshold

500

1000

2000

3000

4000

5000

6000

7000->

0.5

1

2.5

3

3

3

3

3

Trigger 2 (Wired to Bank 1 Inlet CAM)


Trigger 2 Type

Reluctor


Trigger 2 Filtering

Level 1 (Low)


Trigger 2 Arming Threshold

500

1000

2000

3000

4000

5000

6000

7000->

0.5

1

2..5

3

3

3

3

3

VVT Control


Cam Control System

Toyota 1ZZ


Frequency

300 Hz

 