DISCLAIMER

These setting are provided as a general guide only. It is the installers/tuners responsibility to check and confirm that all of these settings are correct for the application.

 

Configuration


Engine Type

4 Stroke


Cylinders/Rotors

6


Firing Order

1-5-3-6-2-4

Ignition Setup


Ignition Mode

Direct Spark


Spark Edge

Falling (Dwell Edge = Rising)


Ignition Delay

Installer to set

Trigger Setup


Trigger Mode

BMW S52

Trigger 1


Trigger 1 Type

Reluctor


Trigger 1 Filtering

Level 1 (Low)


Trigger 1 Arming Threshold

500

1000

2000

3000

4000

5000

6000

7000->

1

3

5

8

8

8

8

8

Trigger 2 (Wired to Exhaust Bank 1 Cam Position Sensor)


Trigger 2 Type

Reluctor


Trigger 2 Filtering

Level 1 (Low)


Trigger 2 Arming Threshold

500

1000

2000

3000

4000

5000

6000

7000->

0.5

2

5

8

8

8

8

8

VVT Control


Cam Control System

BMW Dual Vanos S52


Frequency

50 Hz

Bank 1 Inlet Cam Position Sensor


Pull-up Resistor

Off


Active Edge

Falling

 

For information on VANOS solenoid wiring and modification see BMW VANOS Solenoids

For more information or corrections to this information please contact tech support.