DISCLAIMER

These setting are provided as a general guide only. It is the installers/tuners responsibility to check and confirm that all of these settings are correct for the application.

 

Holden Commodore VN-VR

 

Configuration


Engine Type

4 Stroke


Cylinders/Rotors

6


Firing Order

1-6-5-4-3-2

Ignition Setup


Ignition Mode

Wasted Spark


Spark Edge

Falling (Dwell Edge = Rising)


Ignition Delay

Installer to measure

Trigger Setup


Trigger Mode

Holden V6 Alloytec II VVTi

Trigger 1


Trigger 1 Type

Reluctor


Trigger 1 Filtering

Level 1 (Low)


Trigger 1 Arming Threshold

500

1000

2000

3000

4000

5000

6000

7000->

0.8

0.8

1.5

2.0

2.5

3.0

3.5

3.5

Trigger 2 (Wired to Bank 1 Inlet Cam Position Sensor)


Trigger 2 Type

Optical/Hall


Trigger 2 Pull-up

ON


Trigger 2 Edge

Falling

VVT Control


Cam Control System

Holden V6 VVTi


Frequency

250 Hz

Cam Position Sensors


Pull-up Resistor

ON


Active Edge

Falling

 