For Torque Management Runtimes look here.


Traction Status

Displays the current status of the Traction Control function.

·OFF - Traction Control is turned off.

·OFF: RPM Lockout - Traction control is disabled because the Engine Speed is less than the RPM Lockout setting.

·OFF: TPS Lockout - Traction control is disabled because the TPS (Main) value is less than the TPS Low Lockout setting.

·OFF: Speed Lockout - Traction control is disabled because the Driven Wheel Speed is less than the Speed Lockout setting.

·Ready - Traction control is not disabled and is waiting for slip to occur.

·Active - Slip has occurred and traction control is actively requesting reduced torque values from the Torque Management function.

·Disabled - Traction control is disabled by the Disable Input.

·Off: Torque Module - The Torque Management function is not turned on and so Traction control cannot operate.

 


Active Traction Table

Displays which Slip Threshold Table is currently active.

 


Traction Limit

Displays the current state of the Traction Limit, more details here.

 


Traction Target Slip

The Slip value that Traction Control is targeting. This is also the Slip threshold at which Traction Control will become active and start requesting reduced torque.

This value comes from the currently active Slip Threshold Table and the Slip Threshold Overlay Table if it is turned on.